top of page

UK Designated Standards Radio Equipment: Notice 0145/26

12 hours ago
4 min read

UK Designated Standards Radio Equipment: Notice 0145/26 Adds 8 Standards and Replaces 5 in Great Britain


The UK designated standards radio equipment list has a new update. On 3 November 2026, the UK government published Notice of Publication 0145/26 under the Radio Equipment Regulations 2017 (S.I. 2017/1206). It replaces five standard references with newer versions, adds eight standards that weren't designated before and sets 7 March 2028 as the removal date for the versions it replaces. The notice applies in England, Wales and Scotland.


Background


Designated standards are how manufacturers get a presumption of conformity with the essential requirements of the Radio Equipment Regulations 2017 in Great Britain. They're published under regulation 2A of the regulations, and each new notice amends the previous one. Notice 0145/26 amends Notice 0130/26 of 21 January 2026, which was the last full list. A consolidated list (version 11) was published alongside it on GOV.UK.

Most designated standards mirror the harmonised standards cited for the EU Radio Equipment Directive. When a notice replaces a reference, the old version usually moves to Annex II, where it keeps giving a presumption of conformity until its removal date. After that date, it no longer does.


Key Changes in the UK Designated Standards Radio Equipment List


Five references replaced

Rows 4, 95, 103, 130 and 147 of the list now point to newer versions:

  • EN 50566:2017 with A1:2023 and A2:2025 (RF exposure of hand-held and body-mounted devices, 30 MHz to 6 GHz)

  • EN 302 217-2 V3.4.1 (fixed point-to-point links, 1 GHz to 174.8 GHz)

  • EN 302 372 V3.1.1 (tank level probing radar)

  • EN 303 135 V2.2.1 (coastal surveillance, VTS and harbour radars)

  • EN 303 354 V1.2.1 (amplifiers and active antennas for TV broadcast reception)

The versions they replace (EN 50566 with A1:2023 only, EN 302 217-2 V3.3.1, EN 302 372 V2.1.1, EN 303 135 V2.1.1 and EN 303 354 V1.1.1) move to Annex II. They keep their presumption of conformity until 7 March 2028.


Eight standards added

Rows 181 to 188 are new:

  • EN 300 440-2 V3.1.1, SRD radiodetermination equipment for location tracking at 2.4 to 2.4835 GHz

  • EN 301 489-5 V2.3.1, EMC for PMR and TETRA equipment

  • EN 301 489-13 V2.1.1, EMC for Citizens Band radio

  • EN 301 489-50 V2.4.1, EMC for cellular base stations and repeaters

  • EN 302 065-3-3 V3.1.0, UWB radiodetermination in motor and railway vehicles, 6.0 to 8.5 GHz

  • EN 302 065-4-4 V2.1.1, UWB exterior material sensing for ground-based vehicles below 10.6 GHz

  • EN 303 364-1-1 V1.1.1, primary surveillance radar in the L band

  • EN 305 550-5 V1.1.1, ultra short range communication equipment at 57 to 64 GHz


An infographic titled "UK Radio Equipment: Designated Standards Updated - Notice of Publication 0145/26 (3 Nov 2026)" summarizing regulatory changes for Great Britain, including 5 replaced standards with a removal date of 7 March 2028, 8 newly designated standards, and required compliance actions for manufacturers.


Restrictions to watch

The three new EN 301 489 parts don't cover emissions below 9 kHz, so they give no presumption of conformity for that parameter. EN 301 489-13 V2.1.1 has a second restriction: it gives no presumption for the regulation 6(1)(b) essential requirement where clause 6 of the standard is applied.


Removals already on the calendar

The notice also restates removal dates set earlier. Six references, including EN 301 489-52 V1.2.1 and EN 301 908-13 V13.2.1, lost their presumption of conformity on 15 November 2026. EN 300 220-2 V3.1.1, EN 302 480 V2.2.1 and EN 302 977 V2.1.1 go on 11 June 2027, and EN 301 893 V2.1.1 on 15 May 2028.


What This Means for Manufacturers


Phones, wearables and other body-worn radio products are the most exposed. If a UK Declaration of Conformity cites EN 50566 without A2:2025, it can rely on that version until 7 March 2028, then needs updating. Labs and manufacturers should check whether the A2 changes call for new SAR work or only a documentation update.

Cellular devices whose UK files still cite EN 301 489-52 V1.2.1 or EN 301 908-13 V13.2.1 need attention now, because those versions were removed on 15 November 2026.

The eight new standards give manufacturers of products such as 2.4 GHz location trackers, CB radios, base stations and 60 GHz short-range links a current reference to test against and cite in their UK files.

A removal date affects the presumption of conformity, so products placed on the market after it need to show conformity against a current designated standard or by another route allowed under the regulations.


Certification Impact Summary


Area

Before

After

Impact level

RF exposure, body-worn devices

EN 50566:2017 + A1:2023

EN 50566:2017 + A1:2023 + A2:2025; old version removed 7 March 2028

High

Location-tracking SRDs at 2.4 GHz

EN 300 440-2 V3.1.1 not designated

EN 300 440-2 V3.1.1 designated

Medium

EMC for PMR/TETRA, CB and base stations

These versions not designated

Part 5 V2.3.1, Part 13 V2.1.1 and Part 50 V2.4.1 added, with restrictions

Medium

UWB in vehicles and material sensing

These versions not designated

EN 302 065-3-3 and 4-4 designated

Medium

Fixed links, TLPR, radars, TV amplifiers

Older versions

New versions; old ones removed 7 March 2028

Low

Cellular UE EMC and LTE UE radio

EN 301 489-52 V1.2.1, EN 301 908-13 V13.2.1 listed for removal

Removed 15 November 2026

High


Timeline and Required Actions


Key Dates

Date

Milestone

21 January 2026

Notice 0130/26 sets the previous full list

3 November 2026

Notice 0145/26 published and in effect; consolidated list version 11

15 November 2026

Six earlier references, including EN 301 489-52 V1.2.1, removed

11 June 2027

EN 300 220-2 V3.1.1, EN 302 480 V2.2.1 and EN 302 977 V2.1.1 removed

7 March 2028

Versions replaced by Notice 0145/26 removed

15 May 2028

EN 301 893 V2.1.1 removed


Required Actions for Manufacturers


  1. Pull the standards list from every UK Declaration of Conformity for products sold in Great Britain.

  2. Compare it with Notice 0145/26 and the consolidated list version 11.

  3. Plan updates to EN 50566 A2:2025 for hand-held and body-worn devices before 7 March 2028.

  4. Fix any file that still relies on a reference removed on 15 November 2026.

  5. Check the 9 kHz restriction on the new EN 301 489 parts and cover that range another way if needed.

  6. Update test reports, technical documentation and UK Declarations of Conformity, and keep the EU and GB versions in step.


Conclusion


Notice 0145/26 is a routine update, but it changes the standard behind RF exposure claims for many body-worn products and confirms removal dates that have already arrived. A quick review of your UK Declarations of Conformity now avoids a rushed update in 2028. Contact our team for support with UKCA radio equipment compliance and global market access.


bottom of page